Heatless Twin Tower - Standard Design
*Scroll to the right on mobile to see entire chart
Model |
SCFM |
Air Connection |
MPD-107-1.0NPT |
107 |
1" NPT |
MPD-135-1.0NPT |
135 |
1" NPT |
MPD-200-1.5NPT |
200 |
1-1/2" NPT |
MPD-250-1.5NPT |
250 |
1-1/2" NPT |
MPD-300-1.5NPT |
300 |
1-1/2" NPT |
MPD-400-2.0NPT |
400 |
2" NPT |
MPD-510-2.0NPT |
510 |
2" NPT |
MPD-650-2.0NPT |
650 |
2" NPT |
MPD-770-2.0NPT |
770 |
2" NPT |
MPD-1000-3FLG |
1000 |
3" Flg |
MPD-1200-3FLG |
1200 |
3" Flg |
MPD-1500-4FLG |
1500 |
4" Flg |
MPD-2000-4FLG |
2000 |
4" Flg |
MPD-2600-4FLG |
2600 |
4" Flg |
MPD-3000-6FLG |
3000 |
6" Flg |
Nominal Capacity based on: Ambient temperature 100°F, Inlet temperature 100°F, Inlet pressure 100 psi g. Refer to sizing chart of brochure for other conditions.
* Consult mdi for -100°F pressure dew points
1. Pre & After filters with automatic drain ARE included in the unit price. Filters supplied mounted on Models MPD-200 - MPD-700
2. Standard electrical requirement of 115V/1Ph/60Hz
3. Standard design pressure: 150 psi g
4. If MATTEI MCF/MFF Series filters are not used for protection of the dryer, warranty may be invalid
5. Maximum Inlet Temperature: 120°F
6. Minimum Inlet Temperature: 50°F
Heatless Twin Tower Design with Energy Management System (EMS)
*Scroll to the right on mobile to see entire chart
Model |
SCFM |
Air Connection |
MPD-107-1.0NPT-EMS |
107 |
1" NPT |
MPD-135-1.0NPT-EMS |
135 |
1" NPT |
MPD-200-1.5NPT-EMS |
200 |
1-1/2" NPT |
MPD-250-1.5NPT-EMS |
250 |
1-1/2" NPT |
MPD-300-1.5NPT-EMS |
300 |
1-1/2" NPT |
MPD-400-2.0NPT-EMS |
400 |
2" NPT |
MPD-510-2.0NPT-EMS |
510 |
2" NPT |
MPD-650-2.0NPT-EMS |
650 |
2" NPT |
MPD-770-2.0NPT-EMS |
770 |
2" NPT |
MPD-1000-3FLG-EMS |
1000 |
3" Flg |
MPD-1200-3FLG-EMS |
1200 |
3" Flg |
MPD-1500-4FLG-EMS |
1500 |
4" Flg |
MPD-2000-4FLG-EMS |
2000 |
4" Flg |
MPD-2600-4FLG-EMS |
2600 |
4" Flg |
MPD-3000-6FLG-EMS |
3000 |
6" Flg |
Nominal Capacity based on: Ambient temperature 100°F, Inlet temperature 100°F, Inlet pressure 100 psi g. Refer to sizing chart of brochure for other conditions.
* Consult mdi for -100°F pressure dew points
1. Pre & After filters with automatic drain ARE included in the unit price. Filters supplied mounted on Models MPD-200 - MPD-700
2. Standard electrical requirement of 115V/1Ph/60Hz
3. Standard design pressure: 150 psi g
4. If MATTEI MCF/MFF Series filters are not used for protection of the dryer, warranty may be invalid
5. Maximum Inlet Temperature: 120°F
6. Minimum Inlet Temperature: 50°F
Digital Readout
The Control Center features a backlit four line character display that monitors operation and status. Regenerating countdowns and time remaining are included.
Sequence Annunciator
Indicates the status of each tower. LED’s indicate which tower is “on-line” drying, “off-line” regenerating as well as the regeneration stages.
Manual Stepping
Allows the operator to quickly and safely step the dryer through a complete 8 hour cycle, in a matter of minutes.
ThermaLocTM
The Control Center also controls Mattei’s “ThermaLocTM” heater protection system. ThermaLocTM ensures maximum reliability and eliminates the safety concerns often associated with heat reactivated dryers. Heaters are protected by a totally redundant dual shutdown system that utilizes independent contactors. In addition to the redundant temperature controllers, the system monitors pressure and shuts the heater down in the event of low line pressure. Blower purge dryers have controls to prevent the heater from energizing if the blower is not running.
Dual Mode Heatless Back Up System
Allows the dryer to function in either the primary heated mode or the auxiliary heatless mode. Should the system experience a temporary overload or a heater failure, the dryer can easily be switched over to operate in the heatless mode. This way the dryer will remain on line until such time as service can be conveniently scheduled. The Dual Mode Back Up System offers unparalleled flexibility, eliminates downtime and prevents business interruptions.