AC SERIES BASE MOUNT(1)(2), AIR-COOLED
Model(s): AC 7 LX, AC 7 HX, AC 7 HHX, AC 11 LX, AC 11 HX, AC 11 HHX, AC 30 LX, AC 30 HX, AC 30 HHX, AC 37 LX, AC 37 HX, AC 37 HHX, AC 45 LX, AC 45 HX, AC 45 HHX
*Scroll to the right on mobile to see entire chart
Model |
HP |
kW |
PSIG |
CFM |
dB(A) |
NPT |
AC 7 LX |
10 |
7.5 |
115 |
49 |
67 |
¾" |
AC 7 HX |
10 |
7.5 |
145 |
42 |
67 |
¾" |
AC 7 HHX |
10 |
7.5 |
188 |
34 |
67 |
¾" |
AC 11 LX |
15 |
11 |
115 |
75 |
67 |
¾" |
AC 11 HX |
15 |
11 |
145 |
66 |
67 |
¾" |
AC 11 HHX |
15 |
11 |
188 |
48 |
67 |
¾" |
AC 30 LX |
40 |
30 |
115 |
198 |
68 |
2" |
AC 30 HX |
40 |
30 |
145 |
164 |
68 |
2" |
AC 30 HHX |
40 |
30 |
188 |
129 |
68 |
2" |
AC 37 LX |
50 |
37 |
115 |
240 |
68 |
2" |
AC 37 HX |
50 |
37 |
145 |
199 |
68 |
2" |
AC 37 HHX |
50 |
37 |
188 |
169 |
68 |
2" |
AC 45 LX |
60 |
45 |
115 |
292 |
68 |
2" |
AC 45 HX |
60 |
45 |
145 |
247 |
68 |
2" |
AC 45 HHX |
60 |
45 |
188 |
206 |
68 |
2" |
Working pressures: 109 psig for 115 psig version - 138 psi for 145 psi version - 181 psig for 188 psig version
(1) Available in 208, 230, 460, or 575V/3ph/60hz.
(2) Models 30 through 45 available water-cooled.
Note: Product is built with UL/ETL/CSA approved components. Agency approval is available at no extra cost if specified on initial purchase order. Purchase order must state
UL or CSA approval is required for the entire compressor. May affect lead times.
AC SERIES BASE MOUNT(1)(2), WATER-COOLED
Model(s): AC 30 LWX, AC 30 HWX, AC 30 HHWX, AC 37 LWX, AC 37 HWX, AC 37 HHWX, AC 45 LWX, AC 45 HWX, AC 45 HHWX
*Scroll to the right on mobile to see entire chart
Model |
HP |
kW |
PSIG |
CFM |
dB(A) |
NPT |
AC 30 LWX |
40 |
30 |
115 |
198 |
69 |
2" |
AC 30 HWX |
40 |
30 |
145 |
164 |
69 |
2" |
AC 30 HHWX |
40 |
30 |
188 |
129 |
69 |
2" |
AC 37 LWX |
50 |
37 |
115 |
240 |
69 |
2" |
AC 37 HWX |
50 |
37 |
145 |
199 |
69 |
2" |
AC 37 HHWX |
50 |
37 |
188 |
169 |
69 |
2" |
AC 45 LWX |
60 |
45 |
115 |
292 |
69 |
2" |
AC 45 HWX |
60 |
45 |
145 |
247 |
69 |
2" |
AC 45 HHWX |
60 |
45 |
188 |
206 |
69 |
2" |
Working pressures: 109 psig for 115 psig version - 138 psi for 145 psi version - 181 psig for 188 psig version
(1) Available in 208, 230, 460, or 575V/3ph/60hz.
(2) Models 30 through 45 available water-cooled.
Note: Product is built with UL/ETL/CSA approved components. Agency approval is available at no extra cost if specified on initial purchase order. Purchase order must state
UL or CSA approval is required for the entire compressor. May affect lead times.
AC SERIES - 80 GALLON TANK MOUNT(1)(2)
Model(s): AC 7 LX-TM, AC 7 HX-TM, AC 7 HHX-TM, AC 11 LX-TM, AC 11 HX-TM, AC 11 HHX-TM
*Scroll to the right on mobile to see entire chart
Model |
HP |
kW |
PSIG |
CFM |
dB(A) |
NPT |
AC 7 LX-TM |
10 |
7.5 |
115 |
49 |
67 |
¾" |
AC 7 HX-TM |
10 |
7.5 |
145 |
42 |
67 |
¾" |
AC 7 HHX-TM |
10 |
7.5 |
188 |
34 |
67 |
¾" |
AC 11 LX-TM |
15 |
11 |
115 |
75 |
67 |
¾" |
AC 11 HX-TM |
15 |
11 |
145 |
66 |
67 |
¾" |
AC 11 HHX-TM |
15 |
11 |
188 |
48 |
67 |
¾" |
Working pressures: “LX” 109 psig for 115 psig version - “HX” 138 psi for 145 psi version - “HHX” 180 psi for 188 psi.
(1) Available in 208, 230, 460, or 575V/3ph/60hz.
(2)80 or 120 GALLON TANK MOUNT: Condensate drain and separator kit are standard. Includes pressure gauge, safety valve, and manual tank drain valve.
Note: Product is built with UL/ETL/CSA approved components. Agency approval is available at no extra cost if specified on initial purchase order. Purchase order must state
UL or CSA approval is required for the entire compressor. May affect lead times.
AC SERIES - 120 GALLON TANK MOUNT(1)(2)
Model(s): AC 7 LX-TM 120, AC 7 HX-TM 120, AC 7 HHX-TM 120, AC 11 LX-TM 120, AC 11 HX-TM 120, AC 11 HHX-TM 120
*Scroll to the right on mobile to see entire chart
Model |
HP |
kW |
PSIG |
CFM |
dB(A) |
NPT |
AC 7 LX-TM 120 |
10 |
7.5 |
115 |
49 |
67 |
¾" |
AC 7 HX-TM 120 |
10 |
7.5 |
145 |
42 |
67 |
¾" |
AC 7 HHX-TM 120 |
10 |
7.5 |
188 |
34 |
67 |
¾" |
AC 11 LX-TM 120 |
15 |
11 |
115 |
75 |
67 |
¾" |
AC 11 HX-TM 120 |
15 |
11 |
145 |
66 |
67 |
¾" |
AC 11 HHX-TM 120 |
15 |
11 |
188 |
48 |
67 |
¾" |
Working pressures: “LX” 109 psig for 115 psig version - “HX” 138 psi for 145 psi version - “HHX” 180 psi for 188 psi.
(1) Available in 208, 230, 460, or 575V/3ph/60hz.
(2)80 or 120 GALLON TANK MOUNT: Condensate drain and separator kit are standard. Includes pressure gauge, safety valve, and manual tank drain valve.
Note: Product is built with UL/ETL/CSA approved components. Agency approval is available at no extra cost if specified on initial purchase order. Purchase order must state
UL or CSA approval is required for the entire compressor. May affect lead times.
Advanced System Controllers
MicroC: Standard on Models AC 4 & AC 5
Programmable microprocessor based control and protection system
which controls compressor operation and adapts to the specific
requirements of the air distribution system. MicroC offers a variety
of programming levels and special options for controlling and
analyzing system operation and faults. Advanced programming and
analysis levels are protected by digital codes to avoid unintentional
tampering. MicroC has an integrated memory module that stores the
operational settings and data in case of power outage.
MAESTRO XS : Standard on Models AC 7 and larger
State-of-the-art computerized controller, Maestro XS automatically controls,
monitors and programs the compressor’s operation, and can be connected
to a PC for remote control. In addition to providing all of the features
found in the MicroC, Maestro XS can become master of a multi-compressor
compressed air plant, thus saving on the installation of a dedicated Master
controller, if connected to other compressed air packages equipped with
Maestro XS controllers.
How It Works
Ambient air is drawn through a filter into the compression
chamber consisting of a stator in which an eccentrically
arranged rotor revolves at 1,800 rpm. An air intake valve
automatically adjusts incoming air volume to match your
control scheme. The rotor has longitudinal slots in which the
vanes slide. Zero-wear vanes ride on a thin film of oil and
are held against the stator by centrifugal force. The air
is compressed through the contraction in volume of each
chamber formed by the vanes, the rotor and the stator
wall. Sealing, cooling and lubrication are ensured by the
oil injected into the chamber.
*Scroll to the right on mobile to see entire chart
Description |
Models |
Code |
Condensate drain and separator kit |
AC 7 & 11 AC 30 & 45, AC 30 & 45W |
IF54A34770 IF54A34673 |
High efficiency intake filter kit |
AC 7 & 11 AC 30 & 45, AC 30 & 45W |
IF54A42953 IF54D60751 |
Maestro XS expansion module |
AC 7 & 11 |
AC40C23976 |
Maestro XS converting serial board |
AC 7 & 11 AC 30 & 45, AC 30 & 45W |
AC40C23981 |
Soundproofing intake air duct |
AC 7 & 11 |
IF44A34788 |
Cabinet Heater kit (protects compressor to +14°F ambient) |
AC 7 & 11 AC 30 & 45, AC 30 & 45W |
IF54A38487 IF54A38389 |
Options TANK MOUNTED COMPRESSORS
*Scroll to the right on mobile to see entire chart
Description |
Models |
Code |
High efficiency intake filter kit |
AC 7 & 11 |
IF54A42953 |
Condensate drain and separator kit |
AC 7 & 11 |
IF54A34770 |
Maestro XS expansion module |
AC 7 & 11 |
AC40C23976 |
Maestro XS converting serial board |
AC 7 & 11 |
AC40C23981 |
Soundproofing intake air duct |
AC 7 & 11 |
IF44A34788 |
AC SERIES BASE MOUNT, AIR-COOLED
*Scroll to the right on mobile to see entire chart
Model |
Length (in) |
Width (in) |
Height (in) |
Weight (lbs net) |
AC 7 LX |
49 |
24 |
41 |
485 |
AC 7 HX |
49 |
24 |
41 |
485 |
AC 7 HHX |
49 |
24 |
41 |
485 |
AC 11 LX |
49 |
24 |
41 |
529 |
AC 11 HX |
49 |
24 |
41 |
529 |
AC 11 HHX |
49 |
24 |
41 |
529 |
AC 30 LX |
72 |
38 |
66 |
1,763 |
AC 30 HX |
72 |
38 |
66 |
1,763 |
AC 30 HHX |
72 |
38 |
66 |
1,763 |
AC 37 LX |
72 |
38 |
66 |
1,830 |
AC 37 HX |
72 |
38 |
66 |
1,830 |
AC 37 HHX |
72 |
38 |
66 |
1,830 |
AC 45 LX |
72 |
38 |
66 |
2,073 |
AC 45 HX |
72 |
38 |
66 |
2,073 |
AC 45 HHX |
72 |
38 |
66 |
2,073 |
AC SERIES BASE MOUNT, WATER-COOLED
*Scroll to the right on mobile to see entire chart
Model |
Length (in) |
Width (in) |
Height (in) |
Weight (lbs net) |
AC 30 LWX |
72 |
38 |
66 |
1,807 |
AC 30 HWX |
72 |
38 |
66 |
1,807 |
AC 30 HHWX |
72 |
38 |
66 |
1,807 |
AC 37 LWX |
72 |
38 |
66 |
1,874 |
AC 37 HWX |
72 |
38 |
66 |
1,874 |
AC 37 HHWX |
72 |
38 |
66 |
1,874 |
AC 45 LWX |
72 |
38 |
66 |
2,116 |
AC 45 HWX |
72 |
38 |
66 |
2,116 |
AC 45 HHWX |
72 |
38 |
66 |
2,116 |
AC SERIES - 80 GALLON TANK MOUNT
*Scroll to the right on mobile to see entire chart
Model |
Length (in) |
Width (in) |
Height (in) |
Weight (lbs net) |
AC 7 LX-TM |
54 |
32 |
67 |
795 |
AC 7 HX-TM |
54 |
32 |
67 |
795 |
AC 7 HHX-TM |
54 |
32 |
67 |
795 |
AC 11 LX-TM |
54 |
32 |
67 |
840 |
AC 11 HX-TM |
54 |
32 |
67 |
840 |
AC 11 HHX-TM |
54 |
32 |
67 |
840 |
AC SERIES - 120 GALLON TANK MOUNT
*Scroll to the right on mobile to see entire chart
Model |
Length (in) |
Width (in) |
Height (in) |
Weight (lbs net) |
AC 7 LX-TM 120 |
59 |
32 |
71 |
870 |
AC 7 HX-TM 120 |
59 |
32 |
71 |
870 |
AC 7 HHX-TM 120 |
59 |
32 |
71 |
870 |
AC 11 LX-TM 120 |
54 |
32 |
71 |
915 |
AC 11 HX-TM 120 |
59 |
32 |
71 |
915 |
AC 11 HHX-TM 120 |
59 |
32 |
71 |
915 |