Heatless Twin Tower - Standard Design
*Scroll to the right on mobile to see entire chart
Model |
SCFM |
Heater kW |
Air Connection |
MHD-100-1.0NPT |
100 |
1.5 |
1" NPT |
MHD-135-1.0NPT |
135 |
1.5 |
1" NPT |
MHD-200-1.5NPT |
200 |
3 |
1-1/2" NPT |
MHD-250-1.5NPT |
250 |
3 |
1-1/2" NPT |
MHD-300-1.5NPT |
300 |
4 |
1-1/2" NPT |
MHD-400-2.0NPT |
400 |
6 |
2" NPT |
MHD-500-2.0NPT |
500 |
6 |
2" NPT |
MHD-600-2.0NPT |
600 |
9 |
2" NPT |
MHD-800-2.0NPT |
800 |
9 |
2" NPT |
MHD-1000-3FLG |
1000 |
13 |
3" Flg |
MHD-1200-3FLG |
1200 |
13 |
3" Flg |
MHD-1500-4FLG |
1500 |
18 |
4" Flg |
MHD-2000-4FLG |
2000 |
25 |
4" Flg |
MHD-2600-4FLG |
2600 |
25 |
4" Flg |
MHD-3000-6FLG |
3000 |
30 |
6" Flg |
*Scroll to the right on mobile to see entire chart
Description |
Flow Range @ 100 psi g (7 bar g) |
Dewpoint |
Max Operating Pressure |
Min Operating Pressure |
Max Inlet Temp |
Min Inlet Temp |
Electrical |
MHD-100 - MHD-250 |
100-250 cfm |
-40°F (-40°C) Standard -100°F (-70°C) Optional |
150 psi g (10.3 bar g) |
80 psi g (5.5 bar g) |
120°F (49°C) |
50°F (10°C) |
240V/1PH/60Hz |
MHD-300 - MHD-1200 |
300-1200 cfm |
-40°F (-40°C) Standard -100°F (-70°C) Optional |
150 psi g (10.3 bar g) |
80 psi g (5.5 bar g) |
120°F (49°C) |
50°F (10°C) |
460V/3Ph/60Hz - Control Power: 115V/1Ph/60Hz (575V/3Ph/60Hz Optional) |
MHD-1500 - MHD-8000 |
1500-8000 cfm |
-40°F (-40°C) Standard -100°F (-70°C) Optional |
135 psi g (9.3 bar g) |
80 psi g (5.5 bar g) |
120°F (49°C) |
50°F (10°C) |
460V/3Ph/60Hz - Control Power: 115V/1Ph/60Hz (575V/3Ph/60Hz Optional) |
1. PowerLoc Demand Control Option is an Energy Management system that adjusts energy use to demand. Features automatic demand
control, digital dewpoint readout, 4-20mA analog output (optional) and high humidity alarm with contacts.
2. Above information should be used as a guideline. Flows are at 100 psi g inlet pressure, 100°F inlet temperature and 100°F ambient temperature.
For specific applications, please consult mdi.
3. Weight includes desiccant (shipped loose Models MHD 1500 and up).
4. For sizing at other temperatures and pressures, please consult mdi.
* 575V UNITS ARE AVAILABLE FOR THE CANADIAN MARKET IN PLACE OF 460V
Heatless Twin Tower Design with Energy Management System (EMS)
*Scroll to the right on mobile to see entire chart
Model |
SCFM |
Heater kW |
Air Connection |
MHD-100-1.0NPT-EMS |
100 |
1.5 |
1" NPT |
MHD-135-1.0NPT-EMS |
135 |
1.5 |
1" NPT |
MHD-200-1.5NPT-EMS |
200 |
3 |
1-1/2" NPT |
MHD-250-1.5NPT-EMS |
250 |
3 |
1-1/2" NPT |
MHD-300-1.5NPT-EMS |
300 |
4 |
1-1/2" NPT |
MHD-400-2.0NPT-EMS |
400 |
6 |
2" NPT |
MHD-500-2.0NPT-EMS |
500 |
6 |
2" NPT |
MHD-600-2.0NPT-EMS |
600 |
9 |
2" NPT |
MHD-800-2.0NPT-EMS |
800 |
9 |
2" NPT |
MHD-1000-3FLG-EMS |
1000 |
13 |
3" Flg |
MHD-1200-3FLG-EMS |
1200 |
13 |
3" Flg |
MHD-1500-4FLG-EMS |
1500 |
18 |
4" Flg |
MHD-2000-4FLG-EMS |
2000 |
25 |
4" Flg |
MHD-2600-4FLG-EMS |
2600 |
25 |
4" Flg |
MHD-3000-6FLG-EMS |
3000 |
30 |
6" Flg |
*Scroll to the right on mobile to see entire chart
Description |
Flow Range @ 100 psi g (7 bar g) |
Dewpoint |
Max Operating Pressure |
Min Operating Pressure |
Max Inlet Temp |
Min Inlet Temp |
Electrical |
MHD-100 - MHD-250 |
100-250 cfm |
-40°F (-40°C) Standard -100°F (-70°C) Optional |
150 psi g (10.3 bar g) |
80 psi g (5.5 bar g) |
120°F (49°C) |
50°F (10°C) |
240V/1PH/60Hz |
MHD-300 - MHD-1200 |
300-1200 cfm |
-40°F (-40°C) Standard -100°F (-70°C) Optional |
150 psi g (10.3 bar g) |
80 psi g (5.5 bar g) |
120°F (49°C) |
50°F (10°C) |
460V/3Ph/60Hz - Control Power: 115V/1Ph/60Hz (575V/3Ph/60Hz Optional) |
MHD-1500 - MHD-8000 |
1500-8000 cfm |
-40°F (-40°C) Standard -100°F (-70°C) Optional |
135 psi g (9.3 bar g) |
80 psi g (5.5 bar g) |
120°F (49°C) |
50°F (10°C) |
460V/3Ph/60Hz - Control Power: 115V/1Ph/60Hz (575V/3Ph/60Hz Optional) |
1. PowerLoc Demand Control Option is an Energy Management system that adjusts energy use to demand. Features automatic demand
control, digital dewpoint readout, 4-20mA analog output (optional) and high humidity alarm with contacts.
2. Above information should be used as a guideline. Flows are at 100 psi g inlet pressure, 100°F inlet temperature and 100°F ambient temperature.
For specific applications, please consult mdi.
3. Weight includes desiccant (shipped loose Models MHD 1500 and up).
4. For sizing at other temperatures and pressures, please consult mdi.
* 575V UNITS ARE AVAILABLE FOR THE CANADIAN MARKET IN PLACE OF 460V
PowerLoc Demand Control Option is an Energy Management system that adjusts energy use to demand. Features automatic demand
control, digital dewpoint readout, 4-20mA analog output (optional) and high humidity alarm with contacts.
*Scroll to the right on mobile to see entire chart
Model |
Length (in) |
Width (in) |
Height (in) |
Weight (lbs net) |
MHD-100 |
18 |
31 |
83 |
680 |
MHD-135 |
22 |
40 |
83 |
720 |
MHD-200 |
22 |
40 |
85 |
920 |
MHD-250 |
22 |
40 |
85 |
920 |
MHD-300 |
27 |
43 |
87 |
1,370 |
MHD-400 |
27 |
47 |
88 |
1,400 |
MHD-500 |
27 |
50 |
89 |
2,060 |
MHD-600 |
28 |
52 |
92 |
2,350 |
MHD-800 |
35 |
63 |
93 |
3,035 |
MHD-1000 |
41 |
74 |
102 |
4,195 |
MHD-1200 |
41 |
74 |
113 |
5,215 |
MHD-1500 |
60 |
78 |
113 |
7,765 |
MHD-2000 |
60 |
78 |
110 |
8,565 |
MHD-2600 |
60 |
96 |
112 |
11,562 |
MHD-3000 |
60 |
96 |
112 |
12,002 |